Grease dosing system supply and installation in Dubai
Power Zone Dubai surveys, supplies and installs grease dosing systems for commercial kitchens across Dubai with its own in-house teams and a free quotation.
Dosing units are often sold as a way to keep drains clear between grease trap cleanings, but in Dubai they sit inside clear Dubai Municipality rules for grease traps. This guide explains those rules, what dosing can and cannot do, how to judge a product claim, and how a dosing installation should be surveyed, set up and recorded.
Power Zone surveys, supplies and installs grease dosing systems for Dubai kitchens with its own in-house teams. Dosing never replaces the grease trap: Dubai Municipality's grease trap guideline (DM-SRN-GWTTG-F03) requires approved traps from approved suppliers, cleaning regularly and at least twice a month, and waste transport only by registered vehicles to approved recycling plants. The same guideline strictly forbids acid, caustics, solvents, enzymes or emulsifying agents when cleaning grease traps, so any dosing product used in drain lines must be checked so it does not emulsify grease past the trap. Dosing systems are quoted after a survey of the kitchen drains and trap.
Updated 2026-11-13. Every rule in this guide links to its official source at the end of the page.
Key facts
- Trap first: dosing supports, and never replaces, an approved grease trap (DM-SRN-GWTTG-F03).
- Cleaning: traps cleaned regularly and at least twice a month.
- Forbidden: acid, caustics, solvents, enzymes or emulsifying agents when cleaning grease traps.
- Approved only: traps and suppliers must be approved by Dubai Municipality.
- Waste: only registered vehicles, only to DM-approved recycling plants.
- Penalties: violations under Local Order No. 8 of 2002, including failure to clean the trap.
What grease dosing is
A grease dosing system is a small pump and controller that injects a measured amount of a liquid product into a kitchen's drain line at set times, usually overnight when the kitchen is quiet. The product is normally a biological or bio-enzymatic liquid intended to help break down fats, oils and grease that coat the inside of drain pipes between the sinks and the grease trap. Suppliers often present dosing as a way to reduce drain blockages and odours.
In Dubai, any discussion of dosing has to start with the grease trap, because Dubai Municipality regulates grease traps closely: which traps may be installed, how often they must be cleaned, how the waste is carried away and which substances may not be used when cleaning them. Dosing can only ever be a support to a properly sized, approved and regularly cleaned trap. This guide explains those rules and what a responsible dosing installation looks like.
What Dubai Municipality requires for grease traps
| Item | Requirement | Source |
|---|---|---|
| Approval | Grease traps and their suppliers are approved by Dubai Municipality; installing unapproved traps or dealing with unapproved suppliers is prohibited | DM-SRN-GWTTG-F03 |
| Cleaning frequency | The trap is cleaned regularly and at least twice a month | DM-SRN-GWTTG-F03 |
| Forbidden substances | Strictly forbidden to use acid, caustics, solvents, enzymes or emulsifying agents when cleaning grease traps | DM-SRN-GWTTG-F03 |
| Waste transport | Only registered and approved vehicles may transport and discharge trap waste, only at DM-approved recycling plants | DM-SRN-GWTTG-F03 |
| Minimum capacity by drain size | 3 inch pipe: 800 litres; 4 inch: 2,000 litres; above 4 inch: 4,000 to 9,000 litres, where fixture values are unknown | DM-SRN-GWTTG-F03 Table 4.2 |
| Smaller traps | Only with an undertaking to install a flow control device and increase cleaning frequency to match the recommended capacity | DM-SRN-GWTTG-F03 |
| Violations | Under Local Order No. 8 of 2002: no trap, direct connection of wastewater to the sewer, failure to clean regularly, interfering with trap operation, not cooperating with inspectors | DM-SRN-GWTTG-F03 |
As guidance, these rules mean that the trap, its size, its cleaning schedule and its waste records come first. A dosing unit cannot be used to extend cleaning intervals beyond the at-least-twice-a-month requirement, and it cannot make an undersized or unapproved trap compliant.
Grease dosing is an adjunct to trap maintenance, not a replacement
As guidance, distinguish a biological or enzyme-based dosing device from a grease trap and the licensed management of fats, oils and grease. A dosing system may be proposed for a particular wastewater arrangement, but it cannot be assumed to remove the duty to maintain a grease interceptor, avoid improper oil discharge or arrange approved waste collection. Dubai Municipality's guideline for grease traps and grease-waste transport provides relevant requirements for food establishments. Before offering a dosing unit, review the approved drainage layout, trap location, cooking processes and waste-handling programme, and verify that the particular product and discharge method are permitted. Do not claim a fixed grease-reduction percentage without reliable site measurements and product evidence. The operator should understand that routine inspection and cleaning obligations continue even when an automated dosing device is installed.
Surveying the line and choosing a dosing-system location
As guidance, map the kitchen's sinks, grease interceptor, wastewater branches, accessible pipe sections and the proposed injection point before installation. The unit should be placed where staff can service it without opening hazardous equipment or contaminating food-preparation surfaces. Confirm how the selected device will receive power or control signals, the route and protection for dosing tubing and whether drainage and electrical changes require professional review or approval. A manufacturer may specify acceptable temperature, chemical compatibility and operating conditions; do not substitute a generic device simply because the enclosure fits in the cupboard. Check whether the grease trap remains accessible for inspection and pumping. A contractor should supply a marked-up drawing identifying the injection point, service access and the parts that are not included in the proposed installation.
Bio-enzyme product claims and discharge compatibility
As guidance, ask for the exact dosing fluid, manufacturer safety data, expected operating conditions and its stated purpose. Avoid advertising that an enzyme or bacterial formulation is certain to convert all grease, eliminates odours or makes scheduled trap cleaning unnecessary. Wastewater conditions, detergent use, temperature and grease loads differ across kitchens, and product efficacy should be supported by evidence for the actual setting. The responsible operator must verify any restrictions from the sewer authority or site permits rather than assuming that a commercially available fluid is approved for every drain. Staff should follow the product's handling and storage instructions and prevent unauthorised mixing with other cleaning chemicals. If odours or blockages recur despite dosing, record what happened and investigate the interceptor and line rather than increasing the dose without technical justification.
Installing controls and managing refill schedules
As guidance, specify whether the selected unit uses a timed pump, another type of controller or an integration with operating hours, and how a technician will verify its functional operation. The schedule should be consistent with the manufacturer's documented application and the kitchen's real operating pattern, not a guess about how much fluid will be needed. Plan safe reservoir access, spill containment appropriate to the product, labelling and a clear refill responsibility. At commissioning, record the product type, permitted settings, tank level and the actions staff should take if an alarm or feed fault appears. A dosing unit that has no solution or a blocked tube may be physically installed but not performing as intended. Keep an inspection log and maintain any grease-trap and waste-removal records separately, because automated dosing does not verify sewer compliance.
Dosing-system quotation, verification and handover
As guidance, ask for a proposal that names the unit model, fluid type, compatible line, control arrangement, consumables, estimated service frequency and any modifications to drainage or electrical supply. Distinguish initial installation from a refill subscription, ongoing trap servicing or separate blockage-clearing work. A demonstration at handover should show safe operation, access for refilling, the maintenance record and a process for reporting leaks or malfunctions. Avoid promising a fixed return on investment based on speculative savings in grease disposal or cleaning visits. A reasonable assessment may compare recorded trap conditions and maintenance history over time while acknowledging other changes in kitchen operations. Power Zone lists grease-dosing system supply and installation, but product suitability and pricing require a real site survey.
The ban on enzymes and emulsifiers in trap cleaning
Dubai Municipality's grease trap guideline states that it is strictly forbidden to use acid, caustics, solvents, enzymes or emulsifying agents when cleaning grease traps. Traps are cleaned mechanically: the guideline's procedure removes the grease layer and solids, vacuums out the water, flushes the screen or filter, and cleans the sides and bottom with water.
As guidance, the reason is practical. A grease trap works by letting fats float and solids settle so that cleaner water flows on to the sewer. Products that break grease into fine droplets or keep it in suspension can carry it through the trap and into the public sewer, where it causes the very blockages the trap is meant to prevent. Any dosing product used in a kitchen's drain lines should therefore be checked with the supplier, the trap manufacturer and, where needed, Dubai Municipality, to confirm it will not undermine the trap or conflict with the cleaning rules.
As guidance, a grease trap cleaning carried out to this guideline is a mechanical job, and any contractor's method statement should confirm that none of these substances is used.
What dosing can and cannot do
| What dosing may do (guidance) | What dosing cannot do |
|---|---|
| Help keep branch drains between sinks and the trap freer of grease film | Replace grease trap cleaning or extend it beyond twice a month |
| Reduce some drain odours when combined with good kitchen practice | Make an undersized or unapproved trap compliant |
| Support routine maintenance in kitchens with long drain runs | Remove solid food waste, which must be scraped into bins |
| Run automatically at quiet times | Guarantee a fixed percentage saving on waste collection |
As guidance, the best results come from combining good practices: scraping plates into bins, using sink strainers, wiping pans before washing, emptying hood oil collectors as Dubai Municipality's kitchen guideline requires, and cleaning the trap on schedule. Dosing is a small addition to that routine, not the routine itself.
Where dosing is used in a kitchen
As guidance, dosing is typically injected into the drain line upstream of the grease trap, often at the start of a long branch that serves pot-wash sinks, dishwashers or food preparation sinks, so that the product travels along the pipe that most often accumulates grease. The controller is set to dose when flow is low, usually overnight, so the product has time to act on the pipe walls.
Dosing is not added directly into the grease trap as a cleaning method, because the trap is cleaned mechanically under Dubai Municipality's guideline. The location, product and dose should be agreed after surveying the drain layout, the trap and the kitchen's working hours, as the sections above describe.
Where a kitchen has repeated blockages in one branch, the cause may be a fall that is too shallow, a damaged pipe or a missing strainer rather than grease alone. Power Zone's drain cleaning guide explains how blockages are diagnosed with cameras and cleared.
Trap size and when dosing is not the answer
Dubai Municipality's guideline sets minimum grease trap capacities based on the kitchen's fixtures or, where those are unknown, on the drain pipe size: 800 litres for a 3 inch pipe, 2,000 litres for a 4 inch pipe, and 4,000 to 9,000 litres for larger pipes. Where there is no space for the recommended size, a smaller trap may be proposed only with an undertaking to install a flow control device and to clean more often, so that the trap is not overloaded.
As guidance, a kitchen whose trap fills with grease long before its scheduled cleaning, or whose drains back up regularly, usually has a capacity, flow or cleaning-frequency problem. Dosing will not fix that. The right steps are to check the trap's size against the kitchen's current load, consider a flow control device or more frequent cleaning, and review kitchen practices that send grease and solids to the drain.
Safety: H2S, confined spaces and chemicals
Dubai Municipality's grease trap guideline requires workers to be aware of the dangers of hydrogen sulphide (H2S) and confined space procedures, and requires barriers around the grease trap cleaning area so that kitchen staff do not enter while work is under way. Grease trap waste can release toxic and flammable gases, and large interceptors may be confined spaces.
As guidance, dosing units add their own handling rules: products should be stored in their original labelled containers, away from food and heat, with their safety data sheets available; different products should never be mixed in the same reservoir; and refills should be carried out with gloves and eye protection. Pumps and controllers should be mounted where they cannot be splashed or knocked and where their electrical supply is protected.
Grease from hoods, sinks and dishwashers
As guidance, a large part of the grease that reaches a kitchen's drains comes from washing pots, pans, trays and filters. Dubai Municipality's kitchen guideline requires hood oil collectors to be emptied and cleaned daily and filters to be cleaned at least weekly. As guidance, that collected grease should be handled as waste oil and never poured into sinks or floor drains, where it would load the trap and the drain lines.
Scraping and wiping before washing, using strainers in sinks and floor drains, and keeping fryer oil out of drains do more to protect drains than any dosing product. Power Zone's kitchen hood filters guide explains filter cleaning, and the kitchen exhaust and grease trap guide covers trap cleaning and records.
Choosing and checking a dosing product
As guidance, a dosing product should come with a clear description of what it is, how it works, the recommended dose, its safety data sheet, its storage requirements and its compatibility with drain materials. Claims that a product eliminates all odours, removes the need for trap cleaning or saves a fixed percentage on waste costs should be treated with caution, because results depend on the kitchen, the drains and the cleaning routine.
Above all, the product should not act as an emulsifier that carries grease past the trap, in view of Dubai Municipality's prohibition on emulsifying agents and enzymes in trap cleaning. Asking the supplier to confirm this in writing, and keeping that confirmation with the kitchen's records, protects the operator if questions arise during an inspection.
Setting up and maintaining a dosing unit
- Survey first: map the drains, find the trap, record its size and cleaning schedule, and note where grease accumulates.
- Agree the injection point on the branch that needs it, upstream of the trap.
- Set the timer for low-flow periods and the dose recommended by the product maker.
- Label the reservoir with the product name and never top up with a different product.
- Check monthly: pump operation, tubing, reservoir level and any leaks.
- Review results against trap cleaning reports and blockage records, and adjust or stop if there is no benefit.
Restaurants, hotels and food courts
As guidance, large kitchens with several wash areas and long drain runs to a central interceptor are where dosing is most often considered, because grease can build up in the pipes long before it reaches the interceptor. In these kitchens, a drain survey that shows where grease actually accumulates is the starting point, so that dosing, if used, goes where it is needed rather than at every sink.
Food courts and malls often have shared interceptors serving many tenants. Dubai Municipality's guideline calls these larger traps grease interceptors. One tenant's dosing product passes into the shared system, so building management should approve any dosing installation and keep a list of products used by tenants. Power Zone's commercial building maintenance guide explains how shared kitchen drainage is maintained.
Leased kitchens and shared drains
As guidance, in a leased restaurant the operator usually manages day-to-day kitchen practice, trap cleaning contracts and any dosing unit, while the lease and building rules decide who maintains the drainage and the trap itself. Under Article (16) of Law No. (26) of 2007, unless the parties agree otherwise, the landlord is responsible for maintenance and for repairing defects that affect the tenant's use, so the lease clause on drainage and grease traps is worth reading before installing equipment.
Any dosing unit installed by a tenant should be approved by the landlord or building management, recorded in the fit-out documents and removed or handed over properly at the end of the lease.
How a grease trap works
As guidance, a grease trap slows the wastewater from kitchen sinks and appliances so that fats, oils and grease, which are lighter than water, float to the top, while food solids sink to the bottom. Baffles keep the floating grease and settled solids inside the trap, and the clearer water in the middle flows on to the sewer. The trap works only while there is enough space for grease and solids to collect; once the layers grow too thick, grease starts to pass through.
This is why Dubai Municipality sets a minimum cleaning frequency and minimum sizes. A trap cleaned at least twice a month, sized for the kitchen's flow, keeps enough working space to separate grease. Anything that keeps grease dissolved or in fine droplets, such as hot water surges, strong detergents or emulsifying products, reduces the trap's ability to separate it.
Twice-monthly trap cleaning in practice
Dubai Municipality's guideline requires traps to be cleaned regularly and at least twice a month. As guidance, kitchens commonly meet this through a contract with a cleaning company that uses registered vehicles, scheduled on fixed dates outside service hours, with the kitchen manager confirming each visit. Kitchens with heavy grease loads or smaller traps under an undertaking may need more frequent cleaning.
Each cleaning should produce a record showing the date, the trap cleaned, the contractor and vehicle, and confirmation that the waste went to an approved recycling plant. Keeping these records in the kitchen, alongside any dosing records, answers the most common inspection questions immediately.
The guideline's cleaning procedure is mechanical: removing the grease layer and solids, vacuuming water, flushing the screen or filter and cleaning the sides and bottom with water. The kitchen should not add chemicals, enzymes or emulsifiers before or during the visit.
Odours and drain flies
As guidance, kitchen drain odours often come from grease and food residues in drain lines, dry floor drain traps, or a grease trap that is overdue for cleaning or has a damaged lid seal. Drain flies breed in the film inside drains and traps. Dosing products are sometimes sold for odour control, but no product can reliably remove every odour if the underlying cause is a dirty trap, a broken seal or a dry trap.
The first steps are to check the trap's cleaning date and lid seals, keep floor drain traps topped up with water, clean drain covers and channels, and clear any branch drains that hold standing water. Power Zone's pest control guide covers drain flies and other pests in kitchens.
Cafés, cloud kitchens and small outlets
As guidance, small outlets often have compact under-sink grease traps that fill quickly because of their size. For these kitchens, the most effective measures are strict scraping and wiping before washing, sink strainers, and keeping to the trap cleaning schedule, with more frequent cleaning where the trap is small. A dosing unit rarely makes sense in a small kitchen with a short drain run, because there is little pipe for grease to build up in before the trap.
Cloud kitchens that share drains between several brands need one person responsible for the trap and its records, so that cleaning is not missed when responsibilities are unclear.
What inspectors check
Dubai Municipality's guideline lists violations under Local Order No. 8 of 2002, including not installing a grease trap, deliberately connecting wastewater directly to the sewer, failing to clean the trap regularly, interfering with the trap's operation, and not cooperating with inspectors. As guidance, inspectors therefore look for an approved trap of suitable size, evidence of regular cleaning, intact baffles and lids, no bypass connections, and staff who can show the records.
A dosing unit does not change these checks. If a dosing unit is installed, having its product details and the supplier's written confirmation on compatibility with the trap ready to show helps answer any questions quickly.
Reviewing whether dosing is working
As guidance, a dosing trial is worth reviewing after a few months using the kitchen's own records: the number of drain blockages and call-outs before and after, odour complaints, the condition of the trap at each cleaning, and any change in the time branch drains take to slow down. If there is no clear improvement, the money is better spent on drain cleaning, more frequent trap cleaning or kitchen practices.
A review should also confirm that the trap is still cleaned at least twice a month and that the trap's contents at cleaning look normal, with grease floating and solids settled, rather than a mixed, emulsified layer that suggests grease is not separating well.
Why grease trap waste goes to recycling
Dubai Municipality's guideline requires all grease trap waste to be discharged only at treatment facilities dedicated to recycling it, using registered and approved vehicles. As guidance, this keeps grease out of the public sewer and turns it into a resource rather than a blockage. Products that carry grease past the trap undo this: the grease ends up in the sewer instead of the recycling plant.
For kitchen operators, the simplest way to support this system is to let the trap do its job, keep it clean on schedule, and avoid anything that stops grease from separating.
Hot water, detergents and dishwashers
As guidance, very hot water and strong detergents from dishwashers and pot-wash sinks can keep grease liquid and dispersed long enough to travel through the trap before it cools and sets further down the sewer. Spreading heavy dishwasher discharges over time, scraping and pre-rinsing with cooler water, and following the trap maker's guidance on what may be connected help the trap separate grease properly.
When a kitchen changes its dishwashing equipment or detergent supplier, it is worth checking that the new arrangement does not increase the hot, detergent-heavy flow to the trap, and reviewing the cleaning frequency in the first weeks after the change.
New kitchens and refits
As guidance, a new or refitted kitchen should plan its grease trap from the start: an approved trap from an approved supplier, sized to Dubai Municipality's guidance for the fixtures or drain size, accessible for cleaning trucks and hoses, with lids that seal and a location that does not force cleaning through food areas. Drain branches should be laid with adequate falls and cleanout points so they can be cleared without breaking floors.
Only once the trap and drains are right is it worth considering whether a dosing point on a long branch would help. Building it into the design avoids awkward retrofits later. Power Zone's fit-out guide covers approvals for kitchen fit-outs.
Staff habits that protect the drains
- Scrape plates, pots and trays into bins before washing.
- Wipe pans and fryer baskets with paper before rinsing.
- Keep sink and floor drain strainers in place and empty them daily.
- Collect fryer oil and hood oil collector contents as waste oil, never into drains.
- Report slow drains and odours early, with the location and time.
As guidance, these habits cost little and protect both the trap and the drain lines. A short laminated card above each wash area, in the languages staff use, makes them part of the routine.
Planning drain and trap maintenance together
As guidance, a single maintenance plan for the kitchen's drains, grease trap, hood filters and any dosing unit avoids gaps and duplicated visits. It lists the trap cleaning dates, the drain jetting schedule for problem branches, filter cleaning, dosing unit checks and who is responsible for each. Reviewing the plan every few months against blockage and odour records shows where effort is paying off and where it is not.
Power Zone's annual maintenance contract guide explains how kitchen drainage and exhaust maintenance can be combined into one planned agreement.
Hotels, labour accommodation and central kitchens
As guidance, hotels, labour accommodation and central production kitchens often serve large numbers at fixed meal times, sending heavy grease loads to the drains in short bursts. Dubai Municipality's guideline includes guidance on trap sizing for accommodation kitchens based on their layout and fixtures, and these kitchens often have large interceptors outside the building. Scheduling trap cleaning to suit the load, protecting the interceptor from hot surges, and keeping strict scraping practices matter more than any additive.
Where long underground drain runs connect several kitchens or wash areas to one interceptor, a camera survey of the drains every so often shows whether grease is building up in the pipes. If it is, targeted jetting is usually the first fix, with dosing considered only where build-up returns in the same branch.
Facility managers should keep the interceptor's approval documents, cleaning records and any dosing details in the building's maintenance file, so contractors and inspectors work from the same information.
When a kitchen faces a blockage now
- Stop using the affected sinks and appliances to avoid overflow.
- Check whether the grease trap is full or overdue for cleaning; if so, arrange an approved cleaning.
- If the trap is fine, the blockage is in a branch drain: arrange jetting and a camera check.
- Clean and disinfect any area affected by overflow before resuming food preparation.
- Record the blockage, its cause and the fix, and review kitchen practices that may have caused it.
As guidance, adding a dosing product during an active blockage will not clear it; the blockage must be removed mechanically first. Power Zone's emergency hub explains how to get urgent help.
Ending a dosing contract properly
As guidance, when a kitchen decides to stop dosing, the pump should be switched off and isolated, the remaining product returned to the supplier or disposed of according to its safety data sheet, the injection point capped securely, and the change recorded alongside the trap and drain records. Leaving an unused unit in place with old product in the reservoir creates a hazard and confuses future contractors.
As guidance, it also helps to tell the grease trap cleaning contractor that dosing has stopped, so they can watch for any change in the trap's condition over the next few cleanings and report it.
If dosing is replaced by more frequent trap cleaning or drain jetting, the new schedule should be written into the kitchen's maintenance plan so the change does not lead to gaps.
Common mistakes
| Mistake | Result (guidance) |
|---|---|
| Treating dosing as a substitute for trap cleaning | Overloaded trap, blockages and possible violations |
| Adding enzymes or emulsifiers into the trap during cleaning | Forbidden by Dubai Municipality; grease carried into the sewer |
| Mixing different dosing products in one reservoir | Unpredictable reactions and loss of effect |
| Dosing at every sink without a survey | Wasted product and no change where blockages actually occur |
| Ignoring trap size and flow | Grease passes through regardless of dosing |
| Pouring hood or fryer grease into sinks | Heavy load on drains and trap |
Records to keep
- Grease trap details: approval, size, location and cleaning contractor.
- Trap cleaning dates, at least twice a month, with waste transport records.
- Dosing unit details: location, product, dose settings and supplier's written confirmation on compatibility.
- Product safety data sheet and storage location.
- Monthly dosing unit checks and refills.
- Drain blockage and odour reports, to judge whether dosing is helping.
As guidance, keeping trap and dosing records together lets inspectors see the whole picture in one place and helps the operator decide whether dosing is worth continuing.
Prices and quotations in Dubai
Dosing systems are quoted after a survey of the kitchen's drains and grease trap, because the unit, the number of injection points, the product and the service visits vary. A quotation should list the unit and its mounting, the injection points, the product and its dose, the monthly service and refill arrangement, and what records will be provided. Related service on Power Zone's official Dubai rate card, in AED and excluding 5% VAT:
| Service | Unit | Starting price |
|---|---|---|
| Kitchen drain cleaning | per job | from AED 180 |
See the full Power Zone Dubai rate card.
Questions to ask a dosing supplier
- What exactly is the product, and can you provide its safety data sheet?
- Will it emulsify grease or carry it past the grease trap?
- Where will you inject it, and why there?
- What dose and timing will you set, and how will you check results?
- Does your proposal change the grease trap cleaning schedule? (It should not reduce it below twice a month.)
- What records will you leave after each service visit?
Grease dosing with Power Zone
Power Zone provides grease dosing system supply and installation across Dubai with its own trained teams, part of all seven emirates, 20 in-house teams. Every project starts with a survey of the drains and the grease trap, checks the trap's approval, size and cleaning schedule, and only then proposes whether dosing is useful, where it should go and which product fits. Installations are labelled, serviced monthly and recorded alongside the trap cleaning records.
See also kitchen exhaust and grease traps, drain cleaning, kitchen hood filters, prices and Power Zone Dubai, or request a site survey.
Frequently asked questions
How often must grease traps be cleaned in Dubai?
Dubai Municipality's grease trap guideline requires traps to be cleaned regularly and at least twice a month.
Are enzymes allowed when cleaning grease traps in Dubai?
No. The guideline strictly forbids acid, caustics, solvents, enzymes or emulsifying agents when cleaning grease traps.
Do grease traps need approval in Dubai?
Yes. Traps and their suppliers are approved by Dubai Municipality; unapproved traps or suppliers are prohibited.
Who can carry grease trap waste?
Only registered and approved vehicles, discharging only at Dubai Municipality approved recycling plants.
What size grease trap does a kitchen need?
Where fixture values are unknown, the guideline links minimum capacity to drain size: 800 litres for 3 inch, 2,000 litres for 4 inch, 4,000 to 9,000 litres for larger pipes.
Can a smaller trap be installed if space is tight?
Only with an undertaking to install a flow control device and to clean more often, so the trap matches the recommended capacity.
What are the penalties for grease trap failures?
The guideline cites violations under Local Order No. 8 of 2002, including failure to clean the trap regularly and connecting wastewater directly to the sewer.
Where is a dosing unit usually installed?
As guidance, on the drain branch upstream of the trap where grease accumulates, dosing during quiet periods.
Can dosing products be poured into the trap?
As guidance, no; traps are cleaned mechanically and Dubai Municipality forbids enzymes and emulsifiers when cleaning them.
Who approves dosing in a mall or food court?
As guidance, building management, since products pass into shared interceptors and drains.
What safety risks come with grease traps?
The guideline requires awareness of hydrogen sulphide (H2S) and confined space procedures, and barriers around the cleaning area.
Can a grease dosing unit replace grease-trap cleaning?
Do not assume so. The system is not a substitute for applicable interceptor maintenance or approved grease-waste disposal.
What should be checked before adding an enzyme-dosing unit?
Check the wastewater route, interceptor, product evidence, dosing point, safe access, permissions and compatibility.
Can an enzyme product reliably eliminate every drain odour?
No. Results depend on actual operating conditions and evidence for the product and setting.
What records does an automated dosing system need?
As guidance, record fluid type, controller settings, replenishment, operating checks and any recurring problems.
Can different dosing liquids be mixed together?
Follow manufacturer safety information; do not assume products are compatible or mix chemicals without approval.
Will grease dosing reduce waste collection costs by a fixed percentage?
Do not promise a fixed saving without measured evidence for the particular kitchen.
How does a grease trap separate grease?
As guidance, it slows the flow so grease floats and solids settle, letting clearer water pass to the sewer, as long as there is working space left.
Is dosing worth it in a small café?
As guidance, rarely; short drain runs leave little pipe for grease to build up, so scraping, strainers and on-time trap cleaning matter more.
How do I know if dosing is working?
As guidance, compare blockages, call-outs, odours and trap condition before and after over a few months, and stop if there is no clear improvement.
Can hot dishwasher water affect the grease trap?
As guidance, yes; very hot, detergent-heavy flow can keep grease dispersed so it passes the trap, so spreading discharges and pre-scraping help.
What should a new kitchen plan for its grease trap?
As guidance, an approved trap from an approved supplier, sized to Dubai Municipality's guidance, accessible for cleaning, with sealed lids and well-laid drains.
Will dosing clear a blocked kitchen drain?
As guidance, no; an active blockage must be cleared mechanically by jetting, and the trap checked, before any dosing can help prevent build-up.
What happens when a kitchen stops dosing?
As guidance, isolate the pump, return or dispose of leftover product per its safety data sheet, cap the injection point and record the change.
Should the trap cleaner know about dosing?
As guidance, yes; telling the trap cleaning contractor when dosing starts or stops lets them watch for changes in the trap's condition and report them.
Can tenants install dosing units in a mall kitchen?
As guidance, only with building management's approval, because the product passes into shared drains and interceptors.
Where should dosing products be stored?
As guidance, in their original labelled containers, away from food and heat, with the safety data sheet available, and never mixed with other products.
Does Power Zone install grease dosing systems in Dubai?
Yes. Power Zone surveys the drains and trap, advises whether dosing helps, installs and services the unit, and keeps records with the trap cleaning log.
Sources
- Dubai Municipality, Guideline for maintaining and cleaning grease traps and transporting their waste to the grease trap waste recycling plant (DM-SRN-GWTTG-F03, version 3.0, October 2022)
- Dubai Municipality, Technical Guidelines for Occupational Health and Safety: Kitchen and Food Areas (DM-HSD-GU46-KFPA2, version 3)
- Dubai Legislation Portal, Law No. 26 of 2007 regulating the relationship between landlords and tenants (Article 16)