Kitchen hood filter supply and replacement in Dubai
Power Zone Dubai supplies, cleans and replaces commercial kitchen hood filters across Dubai with its own in-house teams and a free quotation.
Grease filters are the first line of defence between hot cooking fumes and the exhaust duct: when they are right and clean, grease stays out of the ductwork; when they are missing, damaged or overloaded, grease builds up where it becomes a fire and hygiene risk. This guide explains the Dubai Building Code and Dubai Municipality requirements, how to choose and handle filters, and what a proper filter service records.
Power Zone supplies, cleans and replaces commercial kitchen hood filters in Dubai with its own in-house teams. The Dubai Building Code requires Type I hoods wherever cooking appliances produce grease or smoke, and requires those hoods to be equipped with listed grease filters designed for the specific purpose, with hoods installed and maintained to the ASHRAE handbooks, UAE Fire and Life Safety Code Section 2.18 of Chapter 10 and DW/172. Dubai Municipality's kitchen guideline (DM-HSD-GU46-KFPA2) expects a grease filter and oil collector in the hood in a readily accessible position, filters removed and cleaned regularly and at least once a week, and the fan switched off and locked off before cleaning. Filters are quoted by size, type and quantity after the hoods are surveyed.
Updated 2026-11-13. Every rule in this guide links to its official source at the end of the page.
Key facts
- Type I hoods: required where cooking appliances produce grease or smoke (DBC H.4.12.15.2).
- Filters: Type I hoods equipped with listed grease filters designed for the specific purpose.
- Standards: hoods installed and maintained to ASHRAE handbooks, UAE FLSC Section 2.18 Ch. 10 and DW/172.
- Cleaning: remove and clean filters regularly, at least once a week (DM-HSD-GU46-KFPA2).
- Access: grease filter and oil collector in a readily accessible position in the hood.
- Safety: switch the fan off and lock it off before cleaning ducting and fan blades.
Why hood filters matter
In a commercial kitchen, every pan, fryer and grill releases grease-laden vapour that rises into the hood. The grease filters in the hood are designed to catch as much of that grease as possible before the air enters the exhaust duct. Clean, correctly fitted filters keep the duct, the fan and the roof discharge far cleaner, which reduces the fire risk, the odours released outside and the cost and frequency of deep duct cleaning.
When filters are clogged, damaged, missing or replaced with the wrong type, grease passes straight into the ductwork, airflow drops, the kitchen gets hotter and smokier, and the fan works harder. Filters are therefore one of the simplest and most important parts of a kitchen's fire and hygiene routine. This guide brings together what the Dubai Building Code and Dubai Municipality require and how a proper filter service works in practice.
What Dubai rules require
| Item | Requirement | Source |
|---|---|---|
| Hood type | Type I hoods where cooking appliances produce grease or smoke; Type II above dishwashers and light-duty appliances producing only heat or moisture | DBC H.4.12.15.2 |
| Grease filters | Type I hoods equipped with listed grease filters designed for the specific purpose | DBC H.4.12.15.2 |
| Installation and maintenance | Hoods installed and maintained to ASHRAE handbooks, UAE FLSC Section 2.18 Ch. 10 and DW/172 | DBC H.4.12.15.2 |
| Design | Kitchen hood ventilation designed for the type of cooking appliance and hood served | DBC H.4.12.15.1 |
| No obstructions | Fire dampers and similar devices that obstruct exhaust flow not incorporated in kitchen hood ventilation | DBC H.4.12.15.1 |
| Hood fittings | A grease filter and oil collector in the hood in a readily accessible position | DM-HSD-GU46-KFPA2 |
| Cleaning | Remove and clean filters regularly, at least once a week; clean cooker surfaces, hoods and oil collectors daily | DM-HSD-GU46-KFPA2 |
| Safe cleaning | Switch the fan off, allow cooling, and lock off the fan switch or remove the fuse before cleaning ducting and fan blades | DM-HSD-GU46-KFPA2 |
As guidance, these rules work together: the right hood, the right listed filters, accessible fittings and a cleaning routine. A kitchen that meets one but not the others, for example correct filters that are never cleaned, still loses most of the benefit.
Commercial kitchen hood filters: specifying the right replacement
As guidance, a kitchen filter is part of the exhaust system and should be selected against the installed canopy, not solely from a product photograph. Measure the frame and seating arrangement, note the airflow direction and inspect the filter's physical condition, fit and whether grease can bypass the edge. A replacement should be compatible with the hood and its manufacturer's specification and should not obstruct safe operation or maintenance. Do not describe a filter as compliant with a particular fire standard without verified product documentation. Dubai Municipality's kitchen occupational-health guidance and grease-trap methodology provide local operational context, but the full exhaust and fire-protection design may require specialist review. A site survey should record the location of the canopy, access above the cooking line and how used grease-laden filters will be handled without contaminating food-preparation surfaces.
Signs a canopy filter requires inspection or replacement
As guidance, record loaded grease, damage, distortion, corrosion, missing retaining parts and poor seating during a routine kitchen inspection. A filter that looks dirty may be cleanable if its design and manufacturer instructions permit, whereas a damaged element may require replacement. The decision should not be based on a universal cleaning interval that ignores cooking method, operating hours and actual grease production. Reports of poor extraction can originate from other parts of the system, such as the fan, ducts or inadequate makeup air; replacing the filters alone may not fix that issue. Ask staff whether smoke escapes the canopy or unusual grease deposits appear around nearby surfaces. Document these observations and separate the filter supply quote from any duct cleaning, fan repair or ventilation investigation the findings justify.
Filter handling, cleaning and safe installation
As guidance, plan a filter change for a safe service period when kitchen equipment can be isolated or protected according to site procedures. Remove grease-laden elements without dripping onto food or creating a slipping hazard, and use appropriate protective equipment and cleaning arrangements. Follow the manufacturer's cleaning method for reusable filters, rinse and dry them as instructed, and never put a wet, broken or unsuitable element back merely to keep the kitchen operating. Inspect the retaining mechanism and confirm the filters are seated before handing the canopy back to staff. If filters were removed during a comprehensive cleaning, record the condition of adjacent grease trays, accessible duct inlets and fire-protection equipment without disturbing protected systems. Kitchen operations should not resume with missing filters or equipment in an unsafe state. Keep the cleaning and replacement evidence in the property's service register.
Filter stock planning for hotels and high-use kitchens
As guidance, a hotel with several cooking lines may need a register of filter dimensions, hood identification, product reference, cleaning method, replacement date and a designated clean-storage area. Standardise spares only where the actual canopy models and manufacturer requirements match; visually similar baffle filters may differ in frame and fitting. Record how filters are moved between wash and drying areas and the person responsible for checking damaged units. A procurement contract should separate routine cleaned-filter exchange from replacement of discarded or non-reusable parts, with an evidence trail for quantities supplied. Grease production varies by kitchen operation, so maintenance frequencies should follow the equipment instructions, observations and the operator's appropriate safety programme rather than a promotional one-size-fits-all promise. Coordination with duct, fan and grease-management schedules helps avoid repeated service interruptions.
Filter replacement quotations and records
As guidance, request an itemised proposal specifying the number of filters, measured dimensions, approved product reference, reusable or disposable status, handling, cleaning where included, installation and removal of old material. State whether specialist fan or duct work, repair of the canopy, fire-system tests or disposal fees are included; a filter-supply visit should not imply all exhaust-system defects are resolved. Record the date, kitchen area, before-and-after photographs and any remaining visible problem. If an operator asks for a filter advertised as fire-rated, verify the actual manufacturer's evidence and the approved system before making a compliance claim. Power Zone lists kitchen-filter supply and replacement among its commercial-kitchen services; the exact quote should follow a measured survey rather than an invented fixed per-filter price.
Type I and Type II hoods
The Dubai Building Code requires exhaust hoods to be Type I or Type II and designed to capture and confine cooking vapours and residues. Type I hoods are installed where cooking appliances produce grease or smoke, such as fryers, griddles, ranges and grills. Type II hoods are installed above dishwashers and light-duty appliances that produce heat or moisture but not grease or smoke.
Only Type I hoods are required to carry listed grease filters. As guidance, problems often start when a kitchen's menu or equipment changes: a station that was once used for light warming becomes a grill or fryer under a hood that was not designed for grease. Any change in cooking equipment should be checked against the hood type and its filters before the new equipment is used.
What listed grease filters are
The Dubai Building Code requires Type I hoods to be equipped with listed grease filters designed for the specific purpose. As guidance, a listed filter is one that has been tested and listed for use as a grease filter in commercial kitchen hoods, and carries the identification that shows it. Baffle filters made of stainless steel or aluminium are common in commercial hoods because they force the air to change direction so grease droplets separate and drain to the collector.
Mesh filters, improvised panels or filters cut to size from other products may look similar but do not provide the same performance or fire behaviour. A filter must also fit its frame properly: gaps between filters or around the edges let grease bypass the filters altogether. The sections above explain how to specify, handle and record replacement filters.
Weekly cleaning and the daily routine
Dubai Municipality's kitchen guideline sets out a daily cleaning routine that includes cooker surfaces and hoods, and emptying and cleaning oil and condensation in the channels and collectors, and it requires filters to be removed and cleaned regularly, at least once a week. The guideline also calls for the inside surfaces of ducting and the fan blades to be cleaned, with the fan switched off, allowed to cool, and locked off or its fuse removed first.
As guidance, at least once a week is a minimum. Kitchens that fry or grill heavily, run long hours or cook for large numbers may need filters cleaned several times a week or daily to keep them free-flowing. A simple way to set the right frequency is to look at the filters at the end of each day for a couple of weeks and record how quickly they load.
Oil collectors and drip trays under the filters fill up as the filters work, so they belong in the same routine. An overflowing collector drips grease back onto equipment and floors and can become a fire risk in its own right.
Cleaning methods that protect the filter
As guidance, metal baffle filters are usually cleaned by soaking in hot water with a suitable degreaser, then rinsing and drying, or in a commercial dishwasher where the manufacturer allows it. Harsh caustic products can damage aluminium filters, and scraping can bend the baffles so they no longer separate grease properly. Filters should be handled with gloves, as edges can be sharp and residues hot after service.
Filters should go back into the hood dry and in the correct orientation, seated fully in their frame with no gaps. Reinstalling wet filters or leaving gaps lets grease and moisture bypass them. Damaged filters with bent baffles, broken frames or corrosion should be replaced rather than forced back in.
The cleaning area itself matters: degreasers and hot water near food areas need to be managed under the kitchen's hygiene and safety rules. Power Zone's deep cleaning guide covers kitchen deep cleaning more broadly.
Damaged, missing and bypassed filters
As guidance, a hood with one filter missing, a filter removed to improve airflow, or a gap where a filter does not fit, sends grease-laden air straight into the duct. Grease that collects in the duct is far harder and more expensive to remove than grease on a filter, and it is what feeds duct fires. Every filter position in a Type I hood should always be filled with a listed filter of the right size.
Signs of trouble include grease dripping from the hood edges, visible grease on the duct side of the filters, smoke escaping the hood during service, and a kitchen that feels hotter than usual. When these appear, check the filters first, then the fan and the make-up air.
Filters, ducts and fire safety
The Dubai Building Code requires commercial kitchen hoods to be installed and maintained in accordance with Section 2.18 of Chapter 10 of the UAE Fire and Life Safety Code and DW/172, and it does not allow fire dampers or similar devices that obstruct exhaust flow in kitchen hood ventilation systems. It also requires cleanout openings in duct sections that cannot be reached from the entry or discharge, with tight-fitting steel doors, and exhaust fan motors located outside the exhaust airstream.
As guidance, clean filters reduce how quickly grease builds up in ducts, but they do not replace periodic duct and fan cleaning, or the maintenance of the hood's fire suppression system where fitted. Filter changes, duct cleaning and suppression servicing work best when planned together and recorded in one log. Power Zone's kitchen exhaust and grease trap guide covers duct cleaning, and the fire safety maintenance guide covers suppression and alarm systems.
Make-up air and kitchen pressure
The Dubai Building Code requires the replacement air for a commercial kitchen to match the exhaust plus net exfiltration, with every kitchen kept slightly negatively pressurised to adjacent areas, for example −0.25 Pa, to contain odours, and dedicated mechanical make-up air providing not less than 75% and not more than 95% of the extracted air volume. The building housing the kitchen should be slightly positively pressurised to the outside.
As guidance, clogged filters reduce exhaust flow and upset this balance: smoke and heat stay in the kitchen, and odours can move into dining areas. When a kitchen suddenly feels stuffy or smells escape into the restaurant, clean filters and a working fan are the first things to check before adjusting the make-up air.
Domestic kitchen hoods
For homes, the Dubai Building Code requires domestic range hoods that discharge outside to use smooth, airtight sheet metal ducts of galvanised steel, stainless steel, aluminium or copper with a backdraft damper. Ductless range hoods are allowed where installed to the manufacturer's instructions and where mechanical ventilation is otherwise provided.
As guidance, domestic hood filters are usually metal mesh filters that can be washed, and ductless hoods also use charcoal filters that need replacing on the manufacturer's schedule. Clean filters keep the hood effective and reduce grease on kitchen cabinets and ceilings. The rest of this guide focuses on commercial kitchens, where the rules and the risks are greater.
Restaurants, hotels and food courts
As guidance, large kitchens with several hood sections benefit from treating filters as stock, not as one-off purchases: a full spare set for each hood lets staff swap dirty filters for clean ones at the end of service, so the hood is never left without filters while the dirty set is soaking. Labelling filters by hood and position avoids mismatched sizes going back into the wrong frame.
Hotels and banqueting kitchens often have peaks that load filters much faster than normal days. Planning extra filter changes around large events, and recording them, keeps the hoods working and gives the kitchen manager evidence for inspections. Food courts with many tenants on shared exhaust systems need each tenant to keep its own hood filters clean, because one neglected hood can load a shared duct.
Power Zone's commercial building maintenance guide explains how kitchen systems fit into a building's planned maintenance.
Cloud kitchens and small outlets
As guidance, small outlets and cloud kitchens often run long hours in compact spaces with high-grease menus, which loads filters quickly. A short end-of-shift check of each filter, a spare set ready to swap, and a weekly deep clean as a minimum keep the hood effective without stopping service. Where several brands share one kitchen, a single named person should own the filter log so cleaning is not left to chance.
As guidance, small outlets that close for a day each week can use that day for a thorough clean of filters, frames, collectors and the hood canopy, so the weekly minimum is met without disrupting service on busy days.
Small kitchens should also check that filter sizes match the hood when buying replacements online or from general suppliers, since a filter that is slightly too small leaves a gap that lets grease bypass.
Who is responsible in leased kitchens
As guidance, in a leased restaurant or shop the tenant usually operates the kitchen and its daily and weekly cleaning, while the lease and the building's rules decide who maintains the hood, duct and fan. Under Article (16) of Law No. (26) of 2007, unless the parties agree otherwise, the landlord is responsible for maintenance and for repairing defects that affect the tenant's use, so the lease clause on kitchen exhaust maintenance is worth reading carefully.
Whatever the split, filter cleaning is part of daily kitchen operation, and the operator should keep the records. In shared buildings, building management may set rules for kitchen exhaust cleaning to protect common ducts and roofs.
Choosing filter material and size
As guidance, stainless steel baffle filters are durable and tolerate frequent washing, while aluminium filters are lighter and cheaper but more easily damaged by strong cleaning chemicals. The right choice depends on how often filters are cleaned, the cleaning method and the hood design. Whatever the material, the filter must be the listed type the hood is designed for, and the same type should be used across a hood so airflow stays even.
Size is critical. Filters are specified by their nominal height, width and depth, and the hood's frame may take several sizes. Measuring each position, recording it on the hood log and ordering by position avoids filters that are slightly too small, which leave gaps, or too large, which are forced in and bent. Handles make removal safer and quicker for staff during busy services.
Setting the right cleaning frequency
| Kitchen profile | Typical filter cleaning (guidance) | Basis |
|---|---|---|
| Light cooking, short hours | Weekly minimum; check daily | DM minimum once a week |
| Moderate frying and grilling | Several times a week | Guidance; adjust to loading |
| Heavy frying, charbroiling, long hours | Daily, with a spare set | Guidance; adjust to loading |
| Peaks: events, banqueting, Ramadan nights | Extra changes around the peak | Guidance |
As guidance, Dubai Municipality's once-a-week requirement is a floor, not a target. The table above is a starting point; a kitchen sets its own frequency by recording how quickly filters load and cleaning before they reach the point where grease drips or airflow drops. Seasonal and menu changes are good moments to review the schedule.
Staff safety when handling filters
Dubai Municipality's guideline requires the fan to be switched off, allowed to cool, and locked off or its fuse removed before ducting and fan blades are cleaned. As guidance, the same caution applies around filters: let hoods and filters cool after service, wear gloves to protect against sharp edges and hot residues, and keep floors dry and clear while filters are carried to the washing area, because grease and water make floors slippery.
Staff should know how to remove and refit each filter safely, where spare filters are stored, and who to tell when a filter is damaged. A short, practical briefing for new kitchen staff, with the filter log on the wall, makes the routine part of the kitchen's normal closing duties.
Oil collectors, drip trays and waste grease
Dubai Municipality's guideline requires a grease filter and oil collector in the hood and expects oil and condensation in channels and collectors to be emptied and cleaned daily. As guidance, the grease collected should be handled as kitchen waste oil and never poured into sinks or floor drains, where it adds to the load on the grease trap and can block drains.
Power Zone's kitchen exhaust and grease trap guide explains how grease traps are sized, cleaned and recorded under Dubai Municipality's requirements, and how filters, collectors and traps work together to keep grease out of the drains.
What inspections look for
As guidance, inspectors and insurers looking at a commercial kitchen exhaust usually check that each Type I hood has the right listed filters in every position, that filters and collectors are clean, that there is no visible grease build-up beyond the filters, that the fan and duct have been cleaned to schedule, and that records exist. A clean filter on the day of inspection matters less than a log that shows filters are cleaned consistently.
Keeping the filter log, duct cleaning certificates and fire suppression service records together means the kitchen can show its maintenance history in minutes rather than searching for papers during an inspection.
After a flare-up, alarm or fire
As guidance, after any flare-up under a hood, a fire suppression discharge or a fire alarm linked to cooking, filters should be removed and inspected, cleaned or replaced, and the hood, duct and fan checked before cooking resumes. Filters exposed to high heat can warp, which leaves gaps, and suppression agents and smoke residues need cleaning off. The event, the checks and the work done should be recorded.
Power Zone's emergency hub explains how to reach a team quickly when a kitchen needs urgent support to reopen safely.
Planning a filter exchange service
As guidance, larger kitchens often choose a filter exchange service: a supplier brings a clean, inspected set of filters on a fixed schedule, swaps them for the dirty set and takes the dirty set away for cleaning. This keeps the hood fully fitted at all times, saves kitchen staff time and gives a consistent record of each exchange.
A good exchange agreement lists every hood and filter position, the exchange frequency, how damaged filters are replaced, how quickly an extra exchange can be arranged before a peak, and what record is left after each visit. Power Zone's annual maintenance contract guide explains how such services fit into a planned maintenance agreement.
Hood lights, frames and the hood itself
As guidance, the filters sit in a frame or channel that also collects grease, and the hood canopy above and around them collects grease films over time. Cleaning the filters but not the frame and canopy leaves grease that drips back onto filters and equipment. A weekly wipe of the frame, channels and the inside of the canopy, together with the filters, keeps the whole capture area working.
Hood lights should have sealed fittings suitable for kitchen hoods, and broken covers should be replaced promptly so grease does not reach the lamp. Any damage to the hood skin, such as dents near the filter bank, can create gaps around filters and should be repaired.
Where the hood includes a fire suppression system, nozzles and links are part of the canopy and must not be moved or covered during cleaning; their servicing belongs to the fire safety contractor, as Power Zone's fire safety maintenance guide explains.
Signs the filters are working
- Smoke and steam are drawn into the hood across the full width during peak cooking.
- Filters look evenly coated after service and come clean with the normal method.
- There is no grease dripping from hood edges or visible on the duct side of filters.
- Oil collectors fill gradually and are emptied on schedule.
- The kitchen does not feel unusually hot or smoky, and odours stay in the kitchen.
As guidance, these simple checks during a busy service tell a kitchen manager more about the exhaust system than any single inspection, and changes in them are an early warning to check filters, fans and make-up air.
New kitchens and refits
As guidance, when a kitchen is being built or refitted, the hood type, filter sizes and filter access should be agreed with the cooking line-up before the hood is fabricated, so every grease-producing appliance sits under a Type I hood with listed filters that staff can reach safely. The Dubai Building Code requires the hood ventilation to be designed for the type of cooking appliance and hood served, so the equipment list matters from the start.
At handover, the operator should receive the filter specification and quantities for each hood, a spare set, the cleaning method allowed by the maker, and the hood, duct and suppression documentation. Power Zone's fit-out guide covers approvals for kitchen fit-outs in Dubai.
Schools, hospitals and staff canteens
As guidance, institutional kitchens in schools, hospitals, labour accommodation and staff canteens often cook large volumes at fixed times, which loads filters heavily in short bursts. Scheduling filter cleaning immediately after the main service each day, with a spare set, keeps hoods effective without interrupting meal times. Because these kitchens are often run by catering contractors, the contract should state clearly who cleans filters, who replaces damaged ones, and who keeps the log.
Healthcare and education settings also have stricter hygiene expectations, so the cleaning products used on filters and in the washing area should suit food areas and be used as directed. Records should be available to the facility manager as well as the catering contractor.
Budgeting for filters
As guidance, the cost of filters over a year depends less on the purchase price than on how long each filter lasts. Filters that are cleaned gently and on schedule, handled with care and stored properly last much longer than filters that are scraped, soaked in harsh chemicals or forced into frames. A spare set may look like an extra cost, but it avoids running the hood without filters and spreads wear across two sets.
Budgeting for a planned number of replacements each year, rather than buying in emergencies, also makes it easier to keep the right listed type in stock. A filter log that records replacements by position shows which hoods or positions wear filters fastest, which can point to a cooking or airflow issue worth fixing.
Common mistakes
| Mistake | Result (guidance) |
|---|---|
| Using mesh or non-listed filters in a Type I hood | Poor grease capture and unproven fire behaviour |
| Leaving filter positions empty | Grease goes straight into the duct |
| Cleaning only when filters look black | Clogged filters, reduced airflow, smoky kitchen |
| Reinstalling filters wet or the wrong way round | Moisture and grease bypass the filter |
| Forcing bent filters back into frames | Gaps and poor separation |
| Forgetting oil collectors and drip trays | Overflowing grease and fire risk |
| Cleaning ducts or fans with the fan live | Serious injury risk; DM requires the fan to be switched and locked off |
Records and a filter log
- Hood identifier, number of filter positions and filter sizes.
- Filter type and listing information for each replacement.
- Dates of each cleaning and replacement, and who did it.
- Condition notes: damage, gaps, missing filters, grease on the duct side.
- Oil collector and drip tray cleaning dates.
- Links to duct cleaning and fire suppression service records for the same hood.
As guidance, a one-page log per hood kept in the kitchen office is enough. It gives inspectors and insurers a clear record and helps the kitchen manager see when cleaning frequency needs to increase.
Prices and quotations in Dubai
Kitchen hood filters are quoted after a survey of the hoods, because sizes, quantities, materials and access vary widely. A quotation should list each hood, the number and size of filters, the filter type and listing, delivery and fitting, and whether old filters are taken away. Related services on Power Zone's official Dubai rate card, in AED and excluding 5% VAT:
| Service | Unit | Starting price |
|---|---|---|
| Kitchen deep cleaning | per kitchen | from AED 250 |
| Kitchen drain cleaning | per job | from AED 180 |
See the full Power Zone Dubai rate card.
Questions to ask a filter supplier
- Are these listed grease filters designed for commercial kitchen hoods, and can you show the listing?
- Which sizes and how many does each of my hoods need, and how did you measure them?
- What material are they, and which cleaning methods and products does the maker allow?
- Can you supply a spare set so the hood is never without filters during cleaning?
- Will you check the oil collectors, frames and any gaps when fitting?
- What record will you leave after each delivery or exchange?
Kitchen filters with Power Zone
Power Zone provides kitchen filter supply and replacement across Dubai with its own trained teams, part of all seven emirates, 20 in-house teams. Each visit starts by surveying every hood and filter position, then supplies or cleans and refits the right listed filters, checks frames, gaps and oil collectors, and records the work in a filter log for each hood. Problems found in the duct, fan or make-up air are reported in writing for the operator to decide on.
See also kitchen exhaust and grease traps, fire safety maintenance, prices and Power Zone Dubai, or request a site survey.
Frequently asked questions
What filters does the Dubai Building Code require in commercial kitchen hoods?
Type I hoods must be equipped with listed grease filters designed for the specific purpose (DBC H.4.12.15.2).
When is a Type I hood required?
Wherever cooking appliances produce grease or smoke; Type II hoods are for dishwashers and light-duty appliances producing heat or moisture only.
How often must kitchen hood filters be cleaned in Dubai?
Dubai Municipality's kitchen guideline requires filters to be removed and cleaned regularly, at least once a week.
What daily cleaning does Dubai Municipality expect?
Cooker surfaces and hoods cleaned daily, and oil and condensation in channels and collectors emptied and cleaned.
Must the fan be switched off before cleaning?
Yes. The guideline requires the fan to be switched off, allowed to cool and locked off, or its fuse removed, before cleaning ducting and fan blades.
Which standards apply to commercial kitchen hoods?
The Dubai Building Code requires installation and maintenance to the ASHRAE handbooks, UAE FLSC Section 2.18 Chapter 10 and DW/172.
Can a fire damper be fitted in a kitchen hood duct?
No. The code does not allow fire dampers or similar devices that obstruct exhaust flow in kitchen hood ventilation systems.
Why does my kitchen feel smoky even with the hood on?
As guidance, often clogged or missing filters reducing exhaust flow; check filters, then the fan and the make-up air.
What pressure should a commercial kitchen have?
Slightly negative to adjacent areas, for example -0.25 Pa, with make-up air between 75% and 95% of the extracted air volume.
Can I run the hood with a filter missing?
As guidance, no; every filter position in a Type I hood should hold a listed filter so grease does not enter the duct.
Do domestic hood ducts have rules?
Yes. Ducted domestic hoods must discharge outside through smooth, airtight sheet metal ducts with a backdraft damper.
Who cleans filters in a leased restaurant?
As guidance, the operator runs daily and weekly cleaning; the lease decides who maintains the hood, duct and fan.
Does a kitchen hood filter need to match the installed canopy?
Yes. Verify dimensions, retainers, compatibility and the manufacturer's required filter design before ordering.
Is a dirty commercial kitchen filter always disposable?
No. Some filter types may be cleanable under manufacturer instructions, while damaged or unsuitable filters may need replacement.
Does filter replacement include hood and duct cleaning?
Not automatically. Itemise filter supply separately from any duct, fan or fire-system work.
Can a generic filter be described as meeting a fire standard?
Only if the product and installed system have verified relevant documentation supporting that claim.
Should kitchen filters be reinstalled wet?
As guidance, follow the manufacturer's washing and drying instructions before safe reinstallation.
What should the filter exchange record contain?
As guidance, show canopy ID, product reference, quantity, date, cleaning or replacement action and observed defects.
Is once a week enough for kitchen filters?
Dubai Municipality sets at least once a week as a minimum; as guidance, busy frying and grilling kitchens often need more frequent or daily cleaning.
Where should grease from hood collectors go?
As guidance, handle it as kitchen waste oil; never pour it into sinks or floor drains, where it loads the grease trap.
What should happen after a hood flare-up?
As guidance, inspect, clean or replace the filters and check the hood, duct and fan before cooking resumes, and record the event.
Should the hood frame be cleaned with the filters?
As guidance, yes; frames, channels and the canopy collect grease that otherwise drips back onto filters and equipment.
What should a new kitchen receive at handover?
As guidance, the filter specification and quantities for each hood, a spare set, the maker's cleaning method, and hood, duct and suppression documents.
Do spare filter sets save money?
As guidance, yes; a spare set avoids running the hood without filters during cleaning and spreads wear across two sets, so filters last longer.
Can filters be cleaned in a dishwasher?
As guidance, only where the filter maker allows it; otherwise soak in hot water with a suitable degreaser, rinse, dry and refit in the correct orientation.
Why do aluminium filters wear out quickly?
As guidance, strong caustic cleaners and scraping damage aluminium; gentler degreasers and careful handling extend their life.
How should spare filters be stored?
As guidance, clean and dry, flat or upright in a rack away from cooking areas, labelled by hood and position so the right size goes back in.
Do Type II hoods need grease filters?
The Dubai Building Code requires listed grease filters on Type I hoods; Type II hoods serve dishwashers and light-duty appliances that produce no grease or smoke.
Does Power Zone supply and clean kitchen hood filters in Dubai?
Yes. Power Zone surveys each hood, supplies or cleans listed filters, checks frames and collectors, and keeps a filter log for each hood.
Sources
- Dubai Building Code, 2021 Edition: H.4.12.14 domestic kitchen exhaust, H.4.12.15 kitchen hood ventilation, commercial kitchen hoods and make-up air
- Dubai Municipality, Technical Guidelines for Occupational Health and Safety: Kitchen and Food Areas (DM-HSD-GU46-KFPA2, version 3)
- Dubai Legislation Portal, Law No. 26 of 2007 regulating the relationship between landlords and tenants (Article 16)